31. STATOR CASTING
ELEMENTS
M12
bolt studs
jig
inner
mould
CSM disk
coils
CSM strips
CSM disk
outer
mould
The casting is now complete. It should become slightly warm, and harden within
hours. If it does not begin to set within a few hours, then put it in a warm place to
speed up the process.
When the resin is fully hard, remove the casting from the mould. Be patient and
gentle if possible. Remove the jig from the studs. Tap the two moulds apart, using a
bolt in each of the holes around the central hole. Knock the casting out of the outer
mould by turning it over and knocking the edge of the mould gently against the floor.
PMG manual
page 30